Frequently Asked Questions

Q: Should I use a 3-inch or 4-inch lateral drain pipe?

A:

  • Equal rate of water removal: In terms of water entry into the pipe, both 3- and 4-inch 4-row pipes drain water at the same rate, assuming both have 4-rows of perforations. The 4-inch lateral pipe does not drain faster than the 3-inch pipe.
  • Different pipe capacity: The 3-inch pipe has a lower pipe capacity, so it fills with water and reaches its maximum capacity over a shorter length than a 4-inch pipe. Use the maximum lateral length tool to see the difference (change the pipe from 4 to 3 inches).
  • Option to boost performance: A pipe with 8-rows of perforation drains faster than a 4-row pipe, but the 3-inch pipe does not come in 8 rows. The 4-inch pipe comes in 8 rows of perforation that boost drainage performance.
  • Sediment and root clogging risk: The 3-inch pipe clogs sooner if there's sediment entry into the pipe or root clogging because the cross-section area of the pipe is smaller than a 4-inch pipe.
  • Grade error: 3-inch lateral has less grade-error forgiveness. If poor installation results in grade error (an off-grade dip or hump in the pipe), it will be worse in the 3-inch pipe than the 4-inch pipe. The dip of hump can lead to water standing in the pipe, thereby increasing the chance of root clogging.
  • Price: The price difference between 3- and 4-inch is small, so the installer should evaluate if the cheaper pipe is warranted.

 

Q: My established (over 3 years old) alfalfa field has controlled drainage structures. I would like to know how much water I can/should hold back without doing detrimental harm to the roots. What about wheat?

A: During active growth, maintain the water table about 18 to 24 inches below the soil surface to provide adequate drainage of the root zone. When the crop is not actively growing, the water table can be raised to about 12 inches below the soil surface without concern. These depths should be measured at the lowest point in the field.

 

Q: Can I use controlled drainage with clay tile? Will I get tile blowout or sinkhole?

A: If the clay tile is intact and has not collapsed, you should not have tile blowout.

 

Q: Should I invest in subsurface drainage on a rented farm?

A: Tile investment is done by the landowner because it increases the value of the land. In the scenario that the land operator wants to invest in the drainage system, the rental value should not increase as the operator is paying for the drainage system. In addition, the operator and landowner should agree on having a long-term lease that provides enough time to pay off the drainage-installation loan. In other words, the lease term should be greater than the amortization period of the drainage-installation loan. Otherwise, a buyout clause should be added to the lease agreement. For additional information, read this economics page.

 

Q: Does frost depth impact drains?

A: Generally, no. Agricultural subsurface drains are typically installed below the depth reached by frost. One exception is the drainage outlet, where the pipe is exposed. Frost or ice can temporarily restrict a portion of the pipe’s cross-sectional area, but typically does not block the outlet completely.

 

Q: When water is released from a water control structure, does high-velocity flow damage the tile line? Should I remove the stoplogs gradually to prevent this damage?

A: It should not be a problem. The drainage pipe should be designed with a slope that keeps the velocity of a full-flowing pipe within the recommended range. Therefore, there is generally no need to remove the stoplogs gradually.

 

Q: What happens if you install new drains half-way between the existing drains?

A: Adding new drains to the existing system will increase the flow to the main. If the main was sized for the original drain spacing, it may need to be upgraded to handle the additional flow

 

Q: What is piping around pipes?

A: Soil getting pulled into the main pipe from the surrounding soil is called piping. Piping occurs when the main has too much grade, and thereby causing excessive water velocity in the main pipe.

 

Q: If we cut through all the old clay/plastic tile with a new system, will the old tile pose a problem with the new. For example, will there be soft or mushy spots where water might accumulate? Or will the water merely find its way to the new tile?

A: If the broken tile has enough head pressure, it will cause water to come to the surface and cause a wet spot. If the broken tile is cut enough times that there is insufficient head pressure, water will not come to the surface.

 

Q: How to incorporate conservation practices into land leases?

A: Communication and planning are needed for landowners and tenants to include conservation in the land lease. For additional information, see news article.

 

Q: I recently installed new plastic drain pipes, but after a few months, I have water ponding and the drainage outlet was not flowing much. What is the problem?

A: You may have an under-performance issue due to soil compaction. Click here for more information.